Item | Specification |
Installation Type | Rack |
Cabinet installation standard | Cabinet with a depth of 800 mm or above |
Dimensions without packaging (H x W x D) [mm(in.)] | Typical dimensions (excluding the parts protruding from the body): 43.6 mm x 442 mm x 600 mm (1.72 in. x 17.40 in. x 23.62 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 633 mm (1.72 in. x 17.40 in. x 24.92 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 260 mm x 590 mm x 790 mm |
Chassis height [U] | 1 U |
Weight with packaging [kg(lb)] | 15.48 kg (34.13 lb) |
Weight without packaging [kg(lb)] | 10.26 kg (22.62 lb) |
CPU | 2 CPUs, 16 cores/CPU, 2.0 GHz dominant frequency |
Memory | DDR4 DIMM 64GB TOTAL, 32GB/CPU, ECC supported |
Storage | 32GB |
NOR Flash | 64 MB/CPU, 128 MB in total |
Hard disk | Optional. Purchase a hot-swappable 2.5-inch SATA hard disk (240 GB, 960 GB, 1000 GB or 1920 GB) from Huawei on demand. |
Console port | RJ45 |
Eth Management port | RJ45 |
Maximum power consumption [W] | 391 W |
Maximum heat dissipation [BTU/hour] | 1334.1 BTU/hour |
MTBF [years] | 35.14 years |
MTTR [hours] | 1 hours |
Availability | 0.999997 |
Power supply mode | Built-in AC |
Number of power modules | 2 |
Rated input voltage [V] | AC: 100 V to 240 V, 50 Hz/60 Hz |
High-voltage DC: 240 V, DC | |
Input voltage range [V] | AC: 90 V to 290 V, 45 Hz to 65 Hz |
High-voltage DC: 190–290 V, DC | |
Maximum input current [A] | 8 A |
Maximum output power [W] | 600 W |
Types of fans | Pluggable |
Number of fan modules | 4 |
Heat dissipation mode | Absorbing cold air into the device |
Airflow direction | Air flows in from the front panel and exhausts from the rear panel. |
Redundant power supply | 1+1 |
Redundant fans | 3+1 |
Noise at normal temperature (acoustic power) [db(A)] | ≤72dB(A) |
Long-term operating temperature [°C(°F)] | Without hard disk driver: 0°C to 45°C |
With hard disk driver: 5°C to 40°C | |
Storage temperature [°C(°F)] | -40°C to 70°C |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | Without hard disk driver: 0 m to 5000 m |
With hard disk driver: 0 m to 3000 m | |
Storage altitude [m(ft.)] | 0 m to 5000 m |