Description | Part Number | Model | First supported version |
USG6712E-AC Host (20* (SFP+) + 2*QSFP+2*QSFP28 + 2*HA,2AC power supply) | 02352CNL | USG6712E-AC | V600R006C00 |
USG6712E-AC Host(20*(SFP+)+2*QSFP+2*QSFP28+2*HA,2AC power supply) | 02352CNL-001 | USG6712E-AC | V600R007C20SPC600 |
Item | Specification |
Installation Type | Rack |
Cabinet installation standard | Cabinet with a depth of 800 mm or above |
Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 442 mm x 600 mm (1.72 in. x 17.4 in. x 23.62 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 225 mm x 590 mm x 790 mm (8.86 in. x 23.23 in. x 31.1 in.) |
Chassis height [U] | 1 U |
Weight with packaging [kg(lb)] | 17.6 kg (38.8 lb) |
Weight without packaging [kg(lb)] | 12 kg (26.46 lb) |
CPU | 2 CPU, 14 cores/CPU, up to 1.9 GHz |
Memory | DDR4 64GB, 32GB/CPU |
Storage | USG6712E-AC (02352CNL): 32GB |
USG6712E-AC (02352CNL-001): 32 GB | |
NOR Flash | 64MB, 32MB/CPU |
Hard disk | Optional. You can purchase a 2.5-inch SATA hard disk (240 GB/960 GB/1000 GB) from Huawei based on the site requirements. The hard disk is hot swappable. |
Console port | RJ45 |
Eth Management port | RJ45 |
Maximum power consumption [W] | 566 W |
Maximum heat dissipation [BTU/hour] | 1935.27 BTU/hour |
MTBF [years] | 25 years |
MTTR [hours] | 2 hours |
Power supply mode | AC built-in |
Number of power modules | 2 |
Rated input voltage [V] | AC power input: 100 V AC to 130 V AC/200 V AC to 240 V AC, 50/60 Hz |
High-voltage DC power input: 240V | |
Input voltage range [V] | AC power input: 90 V AC to 290 V AC, 47 Hz to 63 Hz |
Rated output power [W] | 800 W (100 V AC to 130 V AC) |
1200 W (200 V AC to 240 V AC) | |
1200 W (240 V DC) | |
Types of fans | Pluggable |
Number of fan modules | 5 |
Heat dissipation mode | The fan module locates at the air exhaust of the system. |
Airflow direction | Air inlet from front and air outlet from rear |
Redundant power supply | 1+1 |
Redundant fans | 4+1 |
Long-term operating temperature [掳C(掳F)] | Without hard disk driver: 0掳C to 45掳C |
With hard disk driver: 5掳C to 40掳C | |
Storage temperature [掳C(掳F)] | -40掳C to 70掳C |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | Without hard disk driver: 0 m to 5000 m |
With hard disk driver: 0 m to 3000 m | |
Storage altitude [m(ft.)] | 0 m to 5000 m |
Our address