Product Model | OceanStor Pacific 9540 | ||
System Architecture | Fully symmetric distributed architecture | ||
Storage Access Protocol | NFS, SMB, POSIX, MPI-IO, HDFS, and S3 | SCSI, iSCSI, and OpenStack Cinder | |
Raw Capacity per Chassis | 216 TB to 576 TB | 216 TB to 576 TB | |
Height per Chassis | 4U | 4U | |
Number of Nodes per Chassis | 1 | 1 | |
Max. Number of Primary Storage Disks per Node | 36 | 36 | |
Primary Storage Disk Type | 3.5-inch HDD | 3.5-inch HDD | |
Processors per Node | 2 x Kunpeng 920 Processors or 2 x Intel® Xeon® Scalable Processors | 2 x Kunpeng 920 Processors or 2 x Intel® Xeon® Scalable Processors | |
Max. Memory per Node | 512 GB | 512 GB, 768 GB, or 1 TB | |
Max. Cache per Node | 4 x NVMe SSDs | 4 x NVMe or SAS SSDs | |
Number of System Disks per Node | 2 x 600 GB SAS HDDs | 2 x 600 GB SAS HDDs | |
Front-End Service Network Type* | • 10 GE, 25 GE, or 100 GE TCP/IP | • 10 GE or 25 GE TCP/IP | |
• 25 GE or 100 GE RoCE | • 25 GE RoCE | ||
• 100 Gbit/s EDR InfiniBand | |||
Storage Network Type | • 10 GE, 25 GE or 100 GE TCP/IP | • 10 GE or 25 GE TCP/IP | |
• 10 GE, 25 GE or 100 GE RoCE | • 25 GE RoCE | ||
• 100 Gb/s InfiniBand | |||
Data Redundancy Protection Mechanism | EC: N + M (M is 2, 3, or 4) | EC: N + M (M is 2, 3, or 4) | |
Data Self-Healing | Automatic concurrent data reconstruction at 2 TB per hour | Automatic concurrent data reconstruction at 4 TB per hour | |
Key Features | • SmartQuota | • SmartThin | |
• SmartTier | • SmartDedupe & SmartCompression | ||
• SmartQoS | • SmartQoS | ||
• SmartEqualizer | • SmartAuditlog | ||
• SmartMulti-Tenant | • SmartEncyption | ||
• SmartEncryption | • HyperSnap | ||
• SmartAuditlog | • HyperClone | ||
• HyperLock(WORM) | • HyperMetro | ||
• HyperSnap | • HyperReplication(S) | ||
• HyperReplication(A) | • HyperReplication(A) | ||
• SmartIndexing | • MultiPool | ||
• Recycle Bin | • DIF | ||
• SmartInterworking | |||
• DIF | |||
• Object Versioning* | |||
• SmartTakeover* | |||
• SmartCompression | |||
• HyperGeoMetro* | |||
• HyperGeoEC* | |||
Storage Management Software | DeviceManager and eService | ||
Chassis Dimensions (H x W x D) | • Kunpeng model: 175 x 447 x 790 mm | • Kunpeng model: 175 x 447 x 790 mm | |
• x86 model: 175 x 447 x 748 mm | • x86 model: 175 x 447 x 748 mm | ||
Max. Weight per Chassis (with Disks) | ≤ 65 kg | ||
Operating Temperature | 5°C to 35°C | ||
Operating Humidity | 8% RH to 90% RH (non-condensing) | ||
Our address