Components | Specification |
Machine type | 7X58 for the compute tray, comprised of two independent servers |
Form factor | Half-wide, 1U server. 2 server per full wide 1U compute tray. |
Processor | Each server: Two Intel Xeon Processor Scalable Family of processors, either Gold or Platinum level processors (formerly codename "Skylake"). Supports processors with up to 28 cores, core speeds up to 3.9 GHz, and TDP ratings up to 205W. Supports "F"-suffix processors with embedded Omni Path fabric. |
Memory | Each server: 12 DIMM sockets (6 DIMMs per processor). Lenovo TruDDR4 RDIMMs, LRDIMMs and 3DS RDIMMs are supported. Each processor has 6 memory channels, with 1 DIMM per channel. |
Memory maximum | Up to 1.5 TB memory with 12x 128 GB 3DS RDIMMs |
Disk drive bays | Each server supports either of: Two 7mm SATA SSDs One 15mm SATA SSD or NVMe SSD (SATA HDD supported via Special Bid) In addition, the server supports M.2 drives with the addition of an M.2 adapter. Note: Drive bays are mutually exclusive with the use of the ML2 slot. |
Maximum internal storage | Each server: 3.84 TB using two 1.92 GB Enterprise Mainstream SATA 2.5" SSDs. |
Storage controllers | 6 Gbps SATA: Onboard SATA AHCI (non-RAID). RAID 0 and 1 with the onboard SATA RAID (Intel RSTe) PCIe x4 NVMe: Onboard NVMe No RAID support Optional M.2 adapter: Single M.2 Adapter: 1x M.2 drive, no RAID Dual M.2 Adapter: 1 or 2x M.2 drives, RAID 0 or 1 with two drives |
Network interfaces | Each server: One Gigabit Ethernet port with an RJ45 connector, based on the Intel Ethernet Connection X722, shared between the operating system and the XClarity Controller (XCC) management processor. One Gigabit Ethernet port dedicated for use with the XCC management processor. Optional network adapters for high-speed InfiniBand or Omni Path Architecture (OPA) communications Enclosure: 10/100 Mb Ethernet port dedicated for use with the Fan and Power Controller (FPC) for systems management |
PCI Expansion slots | Each server: One PCIe 3.0 x24 front-accessible FHHL slot with riser card Planned support: One ML2 x16 front-accessible slot with riser card. SupportsNC-SI. One internal PCIe x16 slot |
Machine type | 5468 |
Form factor | 6U rack-mounted chassis. |
Maximum number of servers supported | Up to 12 compute nodes (2 compute nodes on 1 compute tray) per chassis. |
Servers per 42U rack | Up to 72 servers in six 6U chassis (36U total, leaving space for top-of-rack switches, UPS units, and so on) |