Technical Specifications
| ||
Installation type
|
Rack, Work bench
| |
Height [mm]
|
mm43.6
| |
Depth [mm]
|
mm210
| |
Wide [mm]
|
mm321
| |
Chassis height [U]
|
1 | |
Weight with packaging [kg]
|
2.834 kg (6.25 lb)
| |
Weight without packaging [kg]
|
1.902 kg (4.19 lb)
| |
CPU
|
1.6 GHz, quad-core
| |
Memory
|
2 GB
| |
NAND Flash
|
1 GB
| |
Console port
|
RJ45
| |
RTC
|
Not supported Note: NTP needs to be configured for clock synchronization.
| |
LAN ports
|
4 x GE combo, 4 x GE electrical
| |
WAN ports
|
2 x 10GE optical/2.5GE electrical
| |
Number of service board slots
|
0 | |
MIC slots (default/maximum)
|
0/0
| |
SIC slots (default/maximum)
|
0/0
| |
WSIC slots (default/maximum)
|
0/0
| |
XSIC slots (default/maximum)
|
0/0
| |
Maximum number of FE ports
|
8 | |
Maximum number of GE ports
|
8 | |
Maximum number of 2.5GE ports
|
2 | |
Maximum number of 5GE ports
|
0 | |
Maximum number of 10GE ports
|
2 | |
Maximum number of 25GE ports
|
0 | |
Maximum number of 40GE ports
|
0 | |
Redundant power supply
|
Not supported
| |
Redundant MPUs
|
Not supported
| |
RPS input
|
Not supported
| |
PoE
|
Not supported
| |
IP rating
|
IP20
| |
MTBF [year]
|
59.65
| |
MTTR [h]
|
2 | |
Availability
|
0.9999961723
| |
Maximum power consumption [W]
|
15
| |
Typical power consumption [W]
|
12
| |
Power supply mode
|
AC built-in
| |
Number of power modules
|
1 | |
Input voltage range [V]
|
90 V to 264 V, 47 Hz to 63 Hz
| |
Rated input voltage [V]
|
100 V to 240 V, 50 Hz/60 Hz
| |
Maximum input current [A]
|
1 | |
Maximum output power
|
32
| |
Types of fans
|
None
| |
Number of fan modules
|
0 | |
Heat dissipation mode
|
Natural heat dissipation
| |
Airflow
|
Natural heat dissipation
| |
Noise at normal temperature (acoustic power)
|
0 | |
Storage temperature [°C]
|
-40°C to +70°C (-40°F to +158°F)
| |
Long-term operating temperature [°C]
|
0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
| |
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
| |
Long-term operating altitude [m]
| < 5000 m (16404.2 ft.) | |
Overtemperature alarm
|
Supported
| |
Environmental standards compliance
|
RoHS REACH WEEE
| |
Safety regulation certification
|
IEC 60950-1 IEC 62368-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 GB 4943.1
| |
EMC certification
|
GB/T 9254 EN 55032 EN 55035 CISPR 32 CISPR 35 EN IEC 61000-3-2 EN IEC 61000-3-3 EN50121-1 EN50121-4 FCC CFR Title 47, Part 15, Subpart B ANSI C63.4 ETSI EN 301 489-1 ETSI EN 301 489-52 ETSI EN 300 386 ICES-003 Issue 7 ETSI EN 301 489-3 ETSI EN 301 489-17
| |