Cabinet installation standards
|
Can be installed in a standard 19" 800 mm-deep cabinet. A H w 2.2 m-high N68E cabinet is used by default.
|
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body)
1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
|
|
Chassis height [U]
|
40 U
|
|
Weight without packaging (base configuration) [kg(lb)]
|
133.3 kg (293.93 lb)
|
|
Weight without packaging (full configuration) [kg(lb)]
|
[400G bundle] 350.7 kg (773.29 lb)
[1T bundle] 395.1 kg (871.2 lb)
|
|
Typical power consumption [W]
|
7720 W (fully configured with BSUF-240s)
9040 W (fully configured with BSUF-480s)
12390 W (fully configured with MSUI-1Ts)
|
|
Typical heat dissipation [BTU/hour]
|
25046.9 BTU/hour (fully configured with BSUF-240s)
29329.6 BTU/hour (fully configured with BSUF-480s)
40198.4 BTU/hour (fully configured with MSUI-1Ts)
|
|
MTBF [year]
|
year36.39
|
|
MTTR [hour]
|
hour0.5
|
|
Availability
|
0.999998431
|
|
Power supply mode
|
HVDC built-in
|
|
Maximum number of power chassis inputs
|
(4 channels/PEM)*4 PEMs = (1 channel/PM)*4 PMs*4 PEMs = 16 channels
|
|
Rated input voltage [V]
|
240V/380V
|
|
Input voltage range [V]
|
192 to 288V,264 to 400V
|
|
Maximum input current [A]
|
14 A/single-module
|
|
Maximum input cable diameter [mm²]
|
2.5 mm²
|
|
Front-end circuit breaker/fuse [A]
|
14 A/single-module
[400G bundle] AC device: 10 PMs, with a total of 10 channels of 14 A
[1T bundle] AD device: 14 PMs, with a total of 14 channels of 14 A
|
|
Noise at normal temperature (acoustic power) [dB(A)]
|
NEBS-compliance (
< 78 dBA @ 27°C (80.6°F)) |
|
Number of slots
|
22
|
|
Number of service board slots
|
16
|
|
Switching capacity
|
50.32Tbps(BSUF-1T)
|
|
Redundant MPUs
|
1:1
|
|
Redundant Switch fabrics
|
3+1
|
|
Redundant power supply
|
[400G bundle] 5+5
[1T bundle] 7+1
|
|
Redundant fans
|
[400G bundle] 2 partitions; 2 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
[1T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
|
|
Long-term operating temperature [°C(°F)]
|
0°C to 45°C (32°F to 113°F)
|
|
Short-term operating temperature [°C(°F)]
|
-5°C to 55°C (23°F to 131°F)
|
|
Restriction on the operating temperature variation rate [°C(°F)]
|
≤ 30°C/hour (86°F/hour)
|
|
Storage temperature [°C(°F)]
|
-40°C to 70°C (-40°F to 158°F)
|
|
Long-term operating relative humidity [RH]
|
5% RH to 85% RH, non-condensing
|
|
Short-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
|
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
|
Long-term operating altitude [m(ft.)]
|
≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].)
|
|
Storage altitude [m(ft.)]
|
Less than 5000 m (16404 ft.)
|