| Description | Part Number | Model | First Supported Version | Remarks |
|---|---|---|---|---|
| NE40E-X8A Integrated Chassis AC Components(Including 2 Fan Tray) | 02350AFX | CR5B0BKP0872 | V800R006C20 | - |
| Item | Specification |
|---|---|
| Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
| Dimensions without packaging (H x W x D) [mm(in.)] | 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
| Chassis height [U] | 21 U |
| Weight without packaging (base configuration) [kg(lb)] | 74.5 kg (164.24 lb) |
| Weight without packaging (full configuration) [kg(lb)] | [400G bundle] 184.3 kg (406.31 lb) [1T bundle] 206.5 kg (455.25 lb) |
| Typical power consumption [W] | 4110 W (fully configured with LPUF-240s) 4770 W (fully configured with LPUF-480s) 6520 W (fully configured with LPUI-1Ts) |
| Typical heat dissipation [BTU/hour] | 13334.6 BTU/hour (fully configured with LPUF-240s) 15475.9 BTU/hour (fully configured with LPUF-480s) 21153.6 BTU/hour (fully configured with LPUI-1Ts) |
| MTBF [year] | year22.32 |
| MTTR [hour] | hour0.5 |
| Availability | 0.999997443 |
| Power supply mode | AC built-in |
| Maximum number of power chassis inputs | (4 channels/PEM)*2 PEM=(1 channel/PM)*4 PM*2 PEM=8 channels |
| Rated input voltage [V] | 200 V to 240 V |
| Input voltage range [V] | 180 V to 264 V |
| Maximum input current [A] | 16 A/single-module |
| Maximum input cable diameter [mm²] | Standard C19 cable |
| Front-end circuit breaker/fuse [A] | 16 A/single-module [400G bundle] DC device: 6 PMs, with a total of 6 channels of 16 A [1T bundle] AC device: 8 PMs, with a total of 8 channels of 16 A |
| Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance ( < 78 dBA @ 27°C (80.6°F)) |
| Number of slots | 12 |
| Number of service board slots | 8 |
| Switching capacity | 25.16 Tbps (LPUI-1T) |
| Redundant MPUs | 1:1 |
| Redundant Switch fabrics | 3+1 |
| Redundant power supply | [400G bundle] 3+3 [1T bundle] 4+1 |
| Redundant fans | [400G bundle] 2 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
| Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
| Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
| Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
| Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
| Long-term operating relative humidity [RH] | 5% to 85% RH, non-condensing |
| Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
| Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
1. More than 10 years of in-depth experience in the automotive field and technological innovation ability
2. Multi-brand, Full series. Achieve cooperation with many brands, and provide first-hand vehicle source.
3. The same demand, more abundant vehicle sources; the same product, more favorable price; the same price, shorter delivery time; the same delivery time, more convenient service
4. One-stop service. Vehicle export service capability, serve the whole process.
Q: How about your main products?
روابط سريعة
عنواننا
الطابق 5AF بالكامل، الغرفة 6F605، الطابق 30F بالكامل، مبنى xingguang Yingjing، رقم 119 طريق Shuiyin، منطقة Yuexiu، قوانغتشو.
جميع الحقوق محفوظة © 2024 للأمن. خريطة الموقع