Item | Specification |
Installation Type | Rack |
Desk | |
Wall | |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic: 43.6 mm x 250 mm x 210 mm (1.72 in. x 9.84 in. x 8.27 in.) |
Maximum: 43.6 mm x 250 mm x 215 mm (1.72 in. x 9.84 in. x 8.46 in.) | |
Weight without packaging [kg(lb)] | 1.9kg |
Storage | NAND Flash 2 GB |
Console port | RJ45 |
Maximum power consumption [W] | 25.06 W |
Maximum heat dissipation [BTU/hour] | 85.50 BTU/hour |
Power supply mode | DC adapter |
Service port surge protection | 6 kV in common mode |
Types of fans | None |
Maximum number of physical ports on the entire device | 2 x 10GE (SFP+) + 10 x GE (RJ45) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) (If the altitude is in the range of 1800 m to 5000 m, the temperature decreases by 1°C or 1.8°F every time the altitude increases by 300 m.) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Atmospheric pressure [kPa] | 53kPa - 106kPa ETSI 300 019-2-3 |
Ground | Ground |
USB | 1 x USB 2.0 (host type A) port |
MTBF [year] | 50 year |
MTTR [hour] | 2 hour |